Assigning dsx-1 timeslots to the network interface – Paradyne T1 T1 Access Mux 926x User Manual

Page 93

Advertising
background image

Setting Up

5-39

9161-A2-GH30-30

April 1998

Assigning DSX-1 Timeslots to the Network Interface

DSX-1 timeslots are assigned by channel allocation, where you specify individual
timeslots. The DSX-1 interface must be enabled to assign DSX-1 timeslots to the
Network interface.

Value

Meaning

N

xx

The lower field represents timeslot

xx of the selected Network

interface.

Assigned

The timeslot is already assigned to something other than a DSX-1
timeslot, so it is unavailable. Assigned timeslots cannot be modified
from this screen.

Available

The timeslot is currently unassigned.

D

ss-p/yy

Timeslot

yy of DSX-1 interface p in slot ss is assigned to the

Network timeslot identified right above it (N

xx).

Timeslot assignment rules:

H

Valid Network timeslots are either labeled as Available, or contain a DSX-1
timeslot assignment

H

Valid DSX-1 timeslots are those that are unassigned, and the currently
assigned timeslot

H

Order of display is as follows:

Available is the first selection

— Then, from lowest DSX-1 interface to the highest DSX-1 interface

— Then lowest available timeslot number to the highest available timeslot

number

For example, if the cursor is on a field with the Available value under assigned
timeslot N

xx, pressing the Spacebar causes this field’s values to cycle through all

valid DSX-1 timeslots, starting with D

ss-p/yy, assuming it is unassigned. If

D

ss-p/yy is already assigned, the next valid timeslot in the order described above

is displayed.

Advertising