System health and test status messages, Health and status messages – Paradyne T1 T1 Access Mux 926x User Manual

Page 159

Advertising
background image

Displaying System Information

7-17

9161-A2-GH30-30

April 1998

Table 7-1.

System Status Messages (2 of 2)

Message

What To Do

What It Indicates

Please Wait

Command takes longer than
5 seconds.

1. Wait until message clears.

2. If the message does not

clear within 2 minutes, reset
the device.

User Interface Already
in Use

Access to the user interface
via Telnet is in use; access to
the interface is denied.

IP address and login of the
user currently accessing the
interface are also provided.

1. Wait and try again.

2. Contact IP address user

and request that they log
off.

User Interface Idle

Previously active session is
now closed/ended, and
access via the COM port is
now available.

Log onto the access unit.

Session has ended due to
timeout.

Normal condition; no action
needed.

System Health and Test Status Messages

The System and Test Status screen ( Path:

main

status

system

test status)

displays the following types of messages:

H

Health and Status – Displays Health and status information in priority order
(highest to lowest).

H

Self-Test Results – Displays the results of the power-up self-test
diagnostics.

H

Test Status – Indicates which tests are currently active.

Health and Status Messages

These messages appear in the first column of the System and Test Status screen
in priority (highest to lowest) order, as shown in Table 7-2.

Clear device failure messages from the System Health and Status screen using
the following menu selection sequence:

Main Menu

Control

Clear Device Fail

Advertising