Paradyne T1 T1 Access Mux 926x User Manual

Page 130

Advertising
background image

Setting Up

5-76

9161-A2-GH30-30

April 1998

Table 5-17.

SNMP Trap Options (2 of 3)

Destination

Possible Settings: Default, COM

, FDL1, FDL2, DDL, EDLss-p

Default Setting: Default

Specifies the network destination for the Trap Manager number configuration option.

H

Destination appears for each trap manager specified in the Number of Trap
Managers configuration option.

Default – Uses the default network.

COM – Uses the communication port as the network destination. This selection only
appears if the Communication Port Use configuration option is set to Net Link.

FDL1 – Uses FDL as the network destination on Network Interface 1. This selection
only appears if the Management Link configuration option is set to FDL for the network
interface (see Table 5-1).

FDL2 – Uses FDL as the network destination on Network Interface 2. This selection
only appears if the Management Link configuration option is set to FDL for the network
interface (see Table 5-1).

DDL – Uses DDL as the network destination. This selection only appears if the
management link configuration option is set to DDL for the Network interface (see
Table 5-1).

EDL

ss-p – Uses EDL as the network destination for the synchronous port in slot ss,

port

p.

H

This selection only appears if the EDL Management Link configuration option is
set to Enable for the given slot and port (see Table 5-3).

NOTE:

If the selected network destination link is disabled, the SNMP traps are
discarded. Ensure that an operational link is selected as the default route,
or change the default route if the link becomes nonoperational.

General Traps

Possible Settings: Disable, Warm, AuthFail, Both
Default Setting: Both

Determines if SNMP trap messages for warmStart and/or authenticationFailure events
are sent to the currently configured trap manager(s).

Disable – Does not send trap messages for warmStart or AuthenticationFailure events.

Warm – Sends trap messages for warmStart events.

AuthFail – Sends trap messages for authenticationFailure events.

Both – Sends trap messages for both warmStart and AuthenticationFailure events.

Enterprise Specific Traps

Possible Settings: Enable, Disable
Default Setting: Disable

Determines if trap messages for enterpriseSpecific events are sent to the currently
configured trap manager(s).

Enable – Sends trap messages for enterpriseSpecific events.

Disable – Does not send trap messages for enterpriseSpecific events.