Setting Up

5-45

9161-A2-GH30-30

April 1998

"

Procedure

1. Follow this menu selection sequence:

Configuration Edit/Display

Cross Connect

Sync Data Port

Assignment

2. The Sync Data Port Assignments screen appears. Enter one of the following

into the Assign To field:

If you want to assign to . . .

Then enter . . .

Network interface timeslots

Net1 or Net2

DSX-1 interface timeslots on the 9161
Single T1 NAM

DSX01-1

Another Sync Data port

Port

3. Enter the number of DS0s to allocate.

4. Enter one of the following into the Assign By field:

Enter . . .

To . . .

Channel

Assign ports individually. However, a Sync Data port can be
assigned to multiple timeslots which do not have to be
contiguous. As you assign multiple timeslots to a port, the data
port rate increases by the Port Base Rate defined on the
Synchronous Data Port Options screen (see

Configuring Sync

Data Ports

on page 5-16).

Block

Assign a block of contiguous channels by specifying the number
of DS0s. The number of DS0s is limited to the largest
contiguous block of timeslots, and only starting timeslots that
have enough contiguous timeslots following will be selectable.

ACAMI

Assign a block of contiguous channels as in the Block method,
except that the number of channels assigned is twice the
number of DS0s to allocate. Every other timeslot is filled with all
ones to maintain ones density on the interface.

5. Move the cursor to the next editable timeslot (underlined). Use the spacebar

or type in the desired slot and port. Repeat this step until all desired timeslots
are assigned.

6. Select Save to save the assignments, or press ESC to save and return to the

Cross Connect menu.