Paradyne T1 T1 Access Mux 926x User Manual

Page 28

Advertising
background image

About the T1 Access Mux

1-10

9161-A2-GH30-30

April 1998

H

Extensive Statistics Gathering. Provides a complete view of the network’s
and each data port’s performance through the statistical data collected from
those interfaces to assist in determining the duration of a condition or event.

— A total of 96 intervals (24 hours) of user and Telco statistical data is kept,

seven per screen page, over a 24 hour period, in 15-minute intervals.

— A total of 32 intervals (8 hours) of Synchronous Data Port statistical data

is kept, over an 8 hour period, in 15-minute intervals.

— Quick and easy access to any of the 96 sets of statistics is provided by

selecting a specific interval or occurrence timeframe. (Specifying an
occurrence timeframe is useful when you know about what time a
specific event occurred.)

— You can select a set of statistics to display at the following times:

following an event, preceding an event, immediately preceding and
following an event, or only those statistics that occurred at or after the
event that is the specified interval or time.

— Statistics collected measure or count the following: errored, unavailable,

severely errored, and bursty errored seconds, as well as controlled slip
seconds and loss-of-frame counts. In addition, yellow alarm, loss of
signal, excessive error rate, frame-synchronization bit error, and
line-code violation counts are kept for each 15-minute interval.

— The worst interval for each statistic is provided as an additional aid in

selecting statistical information surrounding trouble spots.

H

Configuration Upload/Download and Software Download Capability.
Provides quick, cost-effective software upgrades, and quick transfer of
configuration options to and from nodes using a standard file transfer protocol
(FTP).

H

Security. Provides multiple levels of security, which prevents unauthorized
access to the unit.

Security can be controlled by:

— Disabling any form of access to the unit.

— Requiring logins (login ID/password/access level combinations), with

three access levels to select from: read-only, limited-access, and
full-access.

— Enabling SNMP management, and specifying a community name and

access level Read or Read/Write.

— Enabling SNMP management, and specifying the IP addresses of only

selected NMSs.

H

Redundant power supply. Redundant load sharing supply (both AC and DC
versions available) for the 5-slot housing and the access carrier. Protects the
system from a service outage if one power supply fails.

H

Wall-Mount Bracket. Allows one 5-slot, or up to two 2-slot housings to be
mounted on a wall.

Advertising