Setting Up

5-11

9161-A2-GH30-30

April 1998

Table 5-1.

Network Interface Options (5 of 7)

Routing Information Protocol

Possible Settings: None, Proprietary
Default Setting: Proprietary

Specifies whether routing information protocol (RIP) is used for routing of management
information between NAMs.

H

Routing Information Protocol only appears if Management Link is set to FDL or
DDL.

None – No routing protocol is used. Use this setting when the device at the other end of
the management link cannot accept routing information.

Proprietary – A proprietary variant of RIP version 1 is used to communicate routing
information between NAMs to enable the routing of IP traffic.

Network Time Slot

Possible Settings: 01 – 24
Default Setting: lowest available time slot

Specifies the time slot for the DDL management link.

H

Network Time Slot only appears appears if Management Link is set to DDL.

NOTE:

If Management Link is not set to DDL, the assigned time slot will be set to
unassigned.

01 – 24 – Valid settings consist of any unassigned time slot within the 01 – 24 range.

Circuit Identifier

Possible Settings: Text Field, Clear
Default Setting: blank

Identifies the transmission vendor’s circuit information for the purpose of facilitating
troubleshooting.

Text Field – Edit or display circuit identifier information (maximum 255 characters).

Clear – Removes the circuit identifier information.

Loss of Signal (LOS) Alarm

Possible Settings: Enable, Disable
Default Setting: Enable

Specifies whether an alarm message is generated when a loss of signal condition is
detected on the network interface.

Enable – Generates an ASCII alarm message.

Disable – Does not generate an ASCII alarm message.

Out of Frame (OOF) Alarm

Possible Settings: Enable, Disable
Default Setting: Enable

Specifies whether an alarm is generated when an out-of-frame condition is detected on
the network interface.

Enable – Generates an alarm message.

Disable – Does not generate an ASCII alarm message.