Table 5-14.

Communication Protocol Options (2 of 3)

Default Network Destination

Possible Settings: None, COM, FDL1, FDL2, DDL, EDL

ss-p

Default Setting: None

Specifies where the default network is connected.

H

Default Network Destination is forced to None if:

– Default Network Destination is set to FDL1, FDL2 or DDL and Network

Interface is set to Disable on the Network Interface Options screen (see

Table 5-1

).

– Management Link on the Network Interface Options screen is changed to a

value inconsistent with the value of Network Interface Destination.

– Default Network Destination is set to COM and COM Port Use is set to

Terminal or Alarms on the Communication Port Options screen (see
T

able 5-10

).

– Default Network Destination is set to EDL

ss-p and EDL Management Link is

set to Disable on the Synchronous Data Port Options screen for Port

p of

Slot

ss (see

Table 5-3

).

None – No default network destination. Data that cannot be routed is discarded.

COM – The communication port is the default network destination. This selection only
appears if Port Use is set to Net Link on the Communication Port Options screen (see

Table 5-10

).

FDL1 – The FDL is the default network destination on Network Interface 1. This
selection only appears if Management Link is set to FDL on the Network Interface 1
Options screen (see

Table 5-1

).

FDL2 – The FDL is the default network destination on Network Interface 2. This
selection only appears if Management Link is set to FDL on the Network Interface 2
Options screen (see

Table 5-1

).

DDL – The DDL is the default network destination. This selection only appears if
Management Link is set to DDL on the Network Interface Options screen (see

Table 5-1

).

EDL

ss-p –The EDL-ss-p port (where ss is the slot number of the NAM or the

synchronous data APM belonging to the ports, and

p is the number of the port). This

selection only appears if EDL Management Link is set to Enable on the Synchronous
Data Port Options screen (see

Table 5-3

) for port

p of slot ss.

Communication Port IP Address

Possible Settings: 000.000.000.000 – 223.255.255.255, Clear
Default Setting: 000.000.000.000

Specifies the IP address needed to access the unit when the COM port is configured as
a network communication link. The IP address is only in effect when the Communication
Port Use configuration option is set to Net Link (see Table 5-10).

000.000.000.000 – 223.255.255.255 – Shows the communication port IP address,
which you can view or edit. The first digit (i.e.,

xxx.255.255.255) cannot be 0 or 127, or

greater than 223. However, 000 is valid, representing a null address.

Clear – Clears the IP address for the communication port and fills the address with
zeros (i.e., 000.000.000.000).