Paradyne T1 T1 Access Mux 926x User Manual

Page 162

Advertising
background image

Displaying System Information

7-20

9161-A2-GH30-30

April 1998

Table 7-2.

Health and Status Messages (3 of 5)

Message

What To Do

What It Indicates

Yellow at DSX

ss-p

A yellow alarm signal is
received on the DSX-1
interface in slot

ss, port p.

DTE has detected an LOS or
OOF condition.

1. Check that the DSX-1 cable

is securely attached at both
ends.

2. Check the status of the

attached equipment.

APM Card Failed,
Slot

ss

The NAM detects an APM
failure for the identified slot.

1

1. Check if APM is removed

from the slot.

2. Remove, then reinstall the

APM.

3. Contact your service

representative.

OOF(EDL), Slot

ss

Port

p

An Out of Frame (OOF)
condition is detected for the
identified slot and port.

1

This

condition occurs when any two
of five consecutive frame
synchronizing bits received
from the remote unit are
incorrect. This condition clears
when a reframe occurs.

1. Cabling problem.

2. T1 facility problem.

1. Check that the far end is

configured for EDL.

2. Contact your network

provider.

EER, Slot

ss Port p

An Excessive Error Rate
(EER) condition is detected for
the identified slot and port.

1

Contact network provider.

Loss of Signal, Slot

ss

Port

p

A Loss of Signal (LOS)
condition has been detected
on the identified OCU-DP
interface. An LOS is declared
when a signal has been
absent on the local loop for
more than two consecutive
seconds.

1. Check that the DSU is

powered up.

2. Check the cable.

Abnormal Station
Code, Slot

ss Port p

An Abnormal Station Code is
being received from the
network DS0 for the identified
OCU-DP interface. This
condition indicates that the
far-end DSU is disconnected
or powered-off.

1. Check the that the far-end

DSU is operational.

2. Check the cable to the

far-end DSU.

1

ss represents physical slots.