Setting Up

5-32

9161-A2-GH30-30

April 1998

Table 5-6.

FXS Voice – Slot ss Port p Options (4 of 4)

Trunk Cond in CGA

Possible Settings: Busy, Idle
Default Setting: Busy

Determines the trunk condition or state that the port is forced into as a result of the
Carrier Group Alarm (CGA).

H

Trunk Cond in CGA only appears if Port Status is set to Enable.

Busy – Forces the port to Busy during the Carrier Group Alarm.

Idle – Forces the port to Idle during the Carrier Group Alarm.

Configuring OCU-DP Ports

Use the OCU-DP Options (

Table 5-7)

to configure the ports (either two or six) on

the OCU-DP APM in the selected slot.

Configuration Edit/Display

OCU-DP Ports

The OCU-DP Options screen appears for Port 1 of the first slot containing an
OCU-DP APM.

Table 5-7.

OCU-DP Options – Slot ss Port p Options (1 of 3)

Port Status

Possible Settings: Enable, Disable
Default Setting: Disable

Specifies whether the OCU-DP port is in use, and can be configured and used to
transmit and receive data.

H

OCU-DP options do not appear if Port Status is set to Disable.

Enable – The port is active, and can be configured used to

Disable – The port is not active, cannot be configured, and cannot transmit/receive
data.

H

No alarms or traps configured for the port will be generated.

H

Existing cross-connect assignments associated with the port will be cleared. The
message This action will clear any Cross Connections for the Port. Are You
Sure?
No appears. If you select:

No – The operation is cancelled. (Pressing either the Esc or Ctrl-a key acts as a
No.)

Yes – Port status is disabled and any cross connections are cleared.