Paradyne T1 T1 Access Mux 926x User Manual

Page 266

Advertising
background image

SNMP Cross-Reference

D-8

9161-A2-GH30-30

April 1998

Table D-1.

SNMP MIB to User Interface Command Cross-Reference (8 of 16)

User Interface Command

SNMP MIB Object

main/test/network and /dsx (cont’d)

Start Monitor QRSS Pattern
Stop Monitor QRSS Pattern

Start Monitor All Zeros Pattern
Stop Monitor All Zeros Pattern

Start Monitor All Ones Pattern
Stop Monitor Alll Ones Pattern

Start Monitor 1 in 8 Pattern
Stop Monitor 1 in 8 Pattern

Start Monitor 3 in 24 Pattern
Stop Monitor 3 in 24 Pattern

Start Monitor 63 Pattern
Stop Monitor 63 Pattern

Start Monitor 511 Pattern
Stop Monitor 511 Pattern

Start Monitor 2047 Pattern
Stop Monitor 2047 Pattern

Start Monitor 2

15

-1 Pattern

Stop Monitor 2

15

-1 Pattern

Start Monitor 2

20

-1 Pattern

Stop Monitor 2

20

-1 Pattern

Start Monitor User-Defined Pattern

Stop Monitor User-Defined Pattern

Inject Error
Clear Monitor Error

Number of Errors Monitored
Number of Errors Injected

Set:

devDS1TestControl for

monQRSS on the interface

devDS1TestControl for

monQRSS to idle on the interface

devDS1TestControl for

monZeros on the interface

devDS1TestControl for

monZeros to idle on the interface

devDS1TestControl for

monOnes on the interface

devDS1TestControl for

monOnes to idle on the interface

devDS1TestControl for

mon1in8 on the interface

devDS1TestControl for

mon1in8 to idle on the interface

devDS1TestControl for

mon3in24 on the interface

devDS1TestControl for

mon3in24 to idle on the interface

devDS1TestControl for

mon63 on the interface

devDS1TestControl for

mon63 to idle on the interface

devDS1TestControl for

mon511 on the interface

devDS1TestControl for

mon511 to idle on the interface

devDS1TestControl for

mon2047 on the interface

devDS1TestControl for

mon2047 to idle on the interface

devDS1TestControl for

mon2E15 on the interface

devDS1TestControl for

mon2E15 to idle on the interface

devDS1TestControl for

mon2E20 on the interface

devDS1TestControl for

mon2E20 to idle on the interface

devDS1TestControl for

monUserDefined on the interface and

devDS1TestArgument to the 2-byte pattern value
devDS1TestControl for

monUserDefined to idle on the interface

devDS1SendControlInjectErr to

inject

devDS1MonResultErrorCount to

clear

Read value in:
devDS1MonResultErrorCount
devDS1SendControlErrorCount