Self-test results messages – Paradyne T1 T1 Access Mux 926x User Manual

Page 164

Advertising
background image

Displaying System Information

7-22

9161-A2-GH30-30

April 1998

Table 7-2.

Health and Status Messages (5 of 5)

Message

What To Do

What It Indicates

Device Fail

yyyyyyyy

The operating software
detects an internal error.
(yyyyyyyy represents an
eight-digit hexadecimal failure
code for use by service
personnel) This condition
clears after a reset of the unit.

Contact your service
representative.

Module MisConfig,
Slot

ss

The APM in slot

xx is not the

one specified in the NAM’s
configuration table.

1, 2

1. Replace the APM with the

type of APM specified by
the configuration table.

2. Change the current

configuration to reflect the
type of APM in the slot. To
do this, edit the
configuration, accept the
APM, then save the
configuration.

Module Unsupported,
Slot

ss

The NAM does not recognize
the APM.

1, 2

A Dual DSX APM has been
installed in a Model 916x T1
Access Unit.

1. Check that an E&M Voice

APM, FXS Voice APM,
FXO Voice APM, Dual DSX
APM, or Sync Data APM is
installed in Slot

ss.

1

2. For Model 926x T1 Access

Mux, check that there is not
more than one DSX APM
installed (only one is
supported).

3. Re-download the NAM

software if new APMs are
supported in later releases.

4. Replace the APM.

5. Contact your service

representative.

Remove the Dual DSX APM.

1

ss represents physical slots.

2

Does not apply to the access carrier.

Self-Test Results Messages

All self-test results messages appear in the middle column of the System and
Test Status screen (see Table 7-3).

Advertising