Data port tests, Dte loopback (dtlb) – Paradyne T1 T1 Access Mux 926x User Manual

Page 210

Advertising
background image

Troubleshooting

9-28

9161-A2-GH30-30

April 1998

Data Port Tests

Data port tests are available to run on any of the synchronous DTE interfaces on
the T1 NAM and the Sync Data APM.

H

Data port loopbacks are defined in ITU V.54 and ANSI T1 403.

H

The Send V.54 Up/Down and FT1 Up/Down perform a similar function to LLB
Up and LLB Down, but are only sent on the DS0s associated with a particular
data port and will control the remote operation of the Data Channel Loopback
(a Sync Data Port test).

H

DTE Payload Loopback on the same port

"

Procedure

To start and stop a data port loopback test:

1. Follow this menu selection sequence:

Main Menu

Test

Sync Data Port Tests

2. Enter the desired slot and port number.

3. Highlight Start under Command in the selected test’s row to send a test.

Then, press Return to start the test.

4. View the length of time that the test has been running in the Results column.

5. Highlight Stop under Command to stop the test.

DTE Loopback (DTLB)

The DTE Loopback (DTLB) performs the same function on the DTE interface that
the LLB does on the Network or DSX-1 interface. Use DTLB for isolating
problems on the DTE interface. An attached device or test equipment must
generate data to be looped back.

496-15213

Network

Interface

DSX

Port

DCE

Port 1

DCE

Port 2

All 1s

The following test cannot be running when a DTLB test is initiated:

H

DTE Payload Loopback on the same port

Advertising