Paradyne T1 T1 Access Mux 926x User Manual

Page 66

Advertising
background image

Setting Up

5-12

9161-A2-GH30-30

April 1998

Table 5-1.

Network Interface Options (6 of 7)

Alarm Indication Signal (AIS) Alarm

Possible Settings: Enable, Disable
Default Setting: Enable

Specifies whether an alarm message is generated when an alarm indication signal
condition is detected on the network interface.

Enable – Generates an ASCII alarm message.

Disable – Does not generate an ASCII alarm message.

Yellow Alarm

Possible Settings: Enable, Disable
Default Setting: Enable

Specifies whether an alarm message is generated when a yellow alarm condition is
detected on the network interface.

Enable – Generates an ASCII alarm message.

Disable – Does not generate an ASCII alarm message.

Excessive Error Rate (EER) Alarm

Possible Settings: Enable, Disable
Default Setting: Enable

Specifies whether an alarm message is generated when an excessive error rate
condition is detected on the network interface.

H

Excessive Error Rate only appears if Line Framing Format is set to ESF.

Enable – Generates an ASCII alarm message.

Disable – Does not generate an ASCII alarm message.