SNMP Traps

C-3

9161-A2-GH30-30

April 1998

Interface

Possible Cause

linkUp/Down
Variable-Bindings

Synchronous
Data Ports

(Supported by the
media-specific
RS232-Like MIB.)

H

ifIndex (RFC 1573)

H

ifAdminStatus
(RFC 1573)

H

ifOperStatus (RFC 1573)

H

i

fType (RFC 1573)

H

linkDown – One or more
alarm conditions are active on
the port.

Alarm conditions include:

– DTR Off

1

– RTS Off

1

– Out of Frame (OOF) for the

Embedded Data Link
(EDL)

2

– Excessive Error Rate for

the Embedded Data Link
(EDL)

2

H

linkUp – No alarms on the
port.

OCU Ports

(Represented by an
entry in the MIB-II
interfaces table.)

H

ifIndex (RFC 1573)

H

ifAdminStatus
(RFC 1573)

H

ifOperStatus (RFC 1573)

H

i

fType (RFC 1573)

H

linkDown – One or more
alarm conditions are active on
the interface.

Alarm conditions include:

– Loss of Signal

– Abnormal Station Code

– 64KCC Loop OOF

– DDS Net Failure

3

– Loss of Loop Timing

H

linkUp – No alarms on the
port.

1

The DTR alarm condition will only generate a linkUp/ linkDown trap if the DTE
supports the DTR lead state (Send All Ones on Data Port Not Ready configuration
option on the

Main Menu

Configuration

Sync Data Ports branch).

2

The OOF and EER alarm condition will only generate a linkUp/ linkDown trap if the
EDL is enabled on that port (Embedded Data Link configuration option on the
Main Menu

Configuration

Sync Data Ports branch).

3

xxxxxx is the failure code