Setting system options – Paradyne T1 T1 Access Mux 926x User Manual

Page 102

Advertising
background image

Setting Up

5-48

9161-A2-GH30-30

April 1998

Setting System Options

Use the System Options screen (see

Table 5-9)

to set the:

H

Generation of yellow alarm signals

H

User-initiated test timeout

H

Clock Source (primary, secondary, external clock rate)

H

Generation of primary/secondary clock failure ASCII alarm messages

Use the following menu selection sequence:

Configuration Edit/Display

System Options

Table 5-9.

System Options (1 of 4)

Generate Yellow Alarm Signals

Possible Settings: Enable, Disable
Default Setting: Enable

Determines whether the T1 access unit generates yellow alarm signals on the network
and DSX-1 Drop/Insert T1 interfaces. The yellow alarm signal is generated in
accordance with AT&T Pub TR 62411 when a continuous LOS/OOF condition (red
Carrier Failure Alarm (CFA) or AIS signal (Blue CFA)) is detected.

H

Generate Yellow Alarm Signals does not appear if:

– DSX-1 Interface on the 9161 Single T1 NAM is set to Disable or,

– 9261 Dual T1 NAM is installed

Enable – The T1 access unit generates yellow alarm signals.

Disable – The T1 access unit does not generate yellow alarm signals.

NOTE:

When this configuration option is disabled, the DTE equipment connected
to the DSX-1 interface is responsible for generation of the yellow alarm
signal for CFAs on the network T1.

Test Timeout

Possible Settings: Enable, Disable
Default Setting: Enable

Determines whether or not user-initiated loopback and pattern tests have a duration
after which they are terminated. This option does not pertain to a DTE-initiated
loopback.

Enable – User-initiated loopback and pattern tests have a timeout. This setting is
recommended when the T1 access unit is managed remotely through an in-band data
stream such as EDL, FDL, or DDL. If the T1 access unit is accidently commanded to
execute a test on the interface providing the management access, control can be
regained after the timeout expires, terminating the test.

Disable – Loopback and pattern tests must be manually terminated.