A-12 – Paradyne T1 T1 Access Mux 926x User Manual

Page 238

Advertising
background image

Menus and Configuration Worksheets

A-12

9161-A2-GH30-30

April 1998

Device Name: ___________________________________________________________

User Interface

Configuration Option

Settings

Default in [Bold]

Communication Port

See Table 5-10

Port Use

[Terminal], Net Link, Alarm

Port Type

[Asynchronous], Synchronous

RIP

1

[None], Proprietary

Port Type – Synchronous

Clock Source

[Internal], External

Data Rate (Kbps)

2

9.6, 14.4, [19.2], 28.8, 38.4, 57.6, 115.2

Port Type – Asynchronous

Data Rate (Kbps)

9.6, 14.4, [19.2], 28.8, 38.4 57.6, 115.2

Character Length

3

7, [8]

Parity

3

[None], Even, Odd

Stop Bits

3

[1], 1.5 ,2

Ignore Control Leads

3

[Disable], DTR

Login Required

4

Enable, [Disable]

Port Access Level

4

[Level-1], Level-2, Level-3

Inactivity Timeout

4

Enable, [Disable]

Disconnect Time (Minutes)

4 ,5

1 – 60

[5]

External Device (COM Port)

See Table 5-11

External Device Commands

[Disable], AT, Other

Dial-In Access

6

Enable, [Disable]

Connect Prefix

7

ASCII text entry, Clear

Connect Indication String

7

ASCII text entry, Clear

Escape Sequence

7

ASCII text entry, Clear

Escape Sequence Delay (Sec)

7

[None], 0.2, 0.4, 0.6, 0.8, 1.0

Disconnect String

7

ASCII text entry, Clear

1

Only shown when Port Use is set to Net Link.

2

Only shown when Clock Source is set to Internal.

3

Only shown when Port Type is set to Asynchronous.

4

Only shown when Port Use is set to Terminal.

5

Only shown when Inactivity Timeout is set to Enable.

6

Only shown when External Device Commands is set to Other or AT.

7

Only shown when External Device Commands is set to Other.

Advertising