Troubleshooting

9-13

9161-A2-GH30-30

April 1998

Table 9-1 lists the alarm messages and corresponding clear messages in
alphabetical order. Priority order is identified. Each alarm message contains:

H

Date and time (

month/day/year hours:minutes:seconds )

that the condition

occurred or was cleared.

H

The user-configured device name.

H

Alarm description.

H

An identification of the affected interface (when applicable).

Table 9-1.

ASCII Alarm Messages (1 of 5)

Message

What It Indicates

What To Do

Priority

month/day/year
hours:minutes:seconds –
An Abnormal Station Code
has been received at the
OCU-DP port in slot

ss

port

p.

An Abnormal Station
Code from the network
DS0 is detected on the
specified OCU-DP
port

1. Check that the

far-end DSU is
operational.

2. Check the far-end

cable to the DSU.

17

month/day/year
hours:minutes:seconds –
Alarm Cleared for Abnormal
Station Code at OCU-DP
port in slot

ss port p.

Alarm condition no
longer exists.

No action needed.

month/day/year
hours:minutes:seconds –
Alarm Indication Signal
(AIS) received at the
Network 1/Network 2
Interface or at the DSX-1
Interface in slot

ss port p.

An Alarm Indication
Signal condition is
detected on the
specified Network or
DSX-1 interface.

Check the status of
the far-end unit. If
necessary, contact
network provider for
Network interface.

Check the DTE
attached to the DSX-1
interface.

6 (Net)
7 (DSX-1)

month/day/year
hours:minutes:seconds –
Alarm Cleared for Alarm
Indication Signal (AIS) at
the Network 1/Network 2)
Interface or at the DSX-1
Interface in slot

ss port p.

Alarm condition no
longer exists.

No action needed.

month/day/year
hours:minutes:seconds –
An APM Card Failure has
been detected for slot

ss.

An APM card failure is
detected for the
identified slot.

1. Check that the APM

card is seated
properly.

2. Contact your

service
representative.

11

month/day/year
hours:minutes:seconds –
Alarm Cleared for an APM
Card Failure for slot

ss.

Alarm condition no
longer exists.

No action needed.