3 application and parameter set transfer, Application and parameter set transfer, Application and parameter set transfer ( 102) – Lenze Engineer v2.21 User Manual

Page 102: Device functions with active online connection, Stop

Advertising
background image

Device functions with active online connection

Application and parameter set transfer

102

Lenze · Engineer · 2.13 EN - 10/2014

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

2. If no online connection to the device has been established yet:

Click the

icon or select the menu command Online Go online to establish an online

connection to the device.

Going online

( 77)

3. Click the

icon or select the menu command Online Stop application.

4. Confirm the safety query on whether the application in the controller is to be stopped with

Yes.

• Then the application in the controller is stopped and controller inhibit is set.

• By clicking

or via the menu command Online Start application you can start the

application in the controller.

The application status is displayed in the status bar.

Status information

( 23)

7.3

Application and parameter set transfer

If an online connection to the device has been established you can transfer the parameter set of the

device to the »Engineer« project, and vice versa. Furthermore you can transfer a (modified)

application from the »Engineer« to the device.

• The transfer functions can be executed via the Toolbar or the Online menu:

Order of data transfer to the device
The data transfer to the device is used to be carried out in the following sequence:

1. Stop devices: In this phase the data transfer is prepared, e.g. controllers are inhibited and

applications are stopped.

2. Transfer data: In this phase, the application, the parameters, and, if so, other data (e.g. cam

data) are transferred (depending on the command selected).

3. Start devices: In this phase the data transfer has been completed. Devices and applications are

started and controller is enabled.

Stop!

If a system module that contains several devices is selected instead of a device in the

Project view, the selected transfer function is executed with all the devices of the system

module to which an online connection has been established.

Icon

Menu command

Shortcut

Download program to device ( 103)

Download parameter set to device ( 105)

<F5>

Upload parameter set ( 106)

<F7>

Save parameter set ( 107)