Mapping the system structure in the »Engineer« project

Protecting safe parameters - project-related password entry

74

Lenze · Engineer · 2.13 EN - 10/2014

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.8

Protecting safe parameters - project-related password entry

This function is available from »Engineer« HighLevel V2.14!

The »Engineer« provides a password protection which serves to protect the parameter setting of the

higher-order safety functions from alterations in the project for the device series 8400 and 9400.
The password...

• ... can be set on the Protection tab if the project root has been selected in the project tree.
• ...is only valid inside the project (no transmission to the controller or safety module). If a

password is stored in the project and this project is used, the safe parameters can only be edited

after the password has been entered.

How to activate the protection of the save parameters:

1. Select the project root

in the project tree.

2. Assign the desired password on the Protection tab.

• After the password has been set, the safe parameters (tab Safe configuration, safe

parameters) of all included devices can only be edited inside the project after the

corresponding password has been entered.