Device functions with active online connection

Manual control of the motor direction of rotation: Rotating the axes manually

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.5

Manual control of the motor direction of rotation: Rotating the axes manually

This function enables the axes to be rotated manually. This allows, for instance, for maintenance

work or diagnostics of the electrical connection.

• The respective axis can be simply rotated with the preset speed setpoint without the need of a

separate control program for motion control.

How to start the function:

Click

in the toolbar.

[7-1]

Example: Manual direction of rotation control with an 8400 TopLine C

Direction of rotation check for multi-axis systems
The direction of rotation control can be used for multi-axis systems with a controller that supports

this function (example: i700 servo inverter).

• The additional selection list serves to select the desired axis which is to be rotated manually.

• If, for instance, the direction of rotation control of Axis A is activated, the direction of rotation

control of the second axis can be activated in addition by selecting Axis B.

• Close the dialog window to deactivate the direction of rotation control in the previously

triggered axes.

Select the desired options:

• Speed: Determine setpoint
• Runtime: Determine period/time after

which the motor stops automatically.

Depending on the device, more options can be

available:

• Current: Enter value [A]
• Axis selection: For controllers which

support a double axis, you can select

between the axes Axis A/Axis B.

Start rotation of the motor: Click .
Stop rotation of the motor: Click .