4 trigger/cursor settings, 5 horizontal settings, 6 recording settings – Lenze Engineer v2.21 User Manual

Page 115: Trigger/cursor settings, Horizontal settings, Recording settings, Device functions with active online connection

Advertising
background image

Lenze · Engineer · 2.13 EN - 10/2014

115

Device functions with active online connection

Data logger

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.7.1.4

Trigger/cursor settings

Trigger
When the Trigger button is active, the input fields for configuring the trigger condition are shown.

Defining the trigger condition

( 118)

Cursor
If the Cursor button is active instead, you can read single measured values of a selectable channel

by means of a vertical measurement line in the diagram. A second vertical measurement line serves

to display the difference between two measured values.

Reading individual measured values

( 121)

7.7.1.5

Horizontal settings

The Horizontal group field serves to define the time base and the horizontal position.

Defining

the recording time/sampling rate

( 117)

7.7.1.6

Recording settings

Use the Recording group field to select the sampling rate and start recording.

• Since the measured data memory has a limited capacity, a compromise must be found between

the sample rate and the recording time that results from the time base setting.

Defining the

recording time/sampling rate

( 117)

Group field

Meaning

Channel

Channel selection

Value

Display of the measured value positioned at the active measurement line

Differential value

Display of the difference between the measured values positioned at the two measurement

lines

Input field

Meaning

Position

Definition of the horizontal display position

• You can either enter a value directly into the input field or define the position by the

arrow buttons.

• When pressing the arrow buttons and the <Ctrl> key at the same time, you can increase

the increment to accelerate the shift.

Time base [1/Div]

Selection of the time base

• The current time base setting multiplied by ten results in the recording time.

• Change the time base to stretch or compress measurements that have already been

completed.