Device functions with active online connection

Application and parameter set transfer

104

Lenze · Engineer · 2.13 EN - 10/2014

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4. Select the parameters/files to be transmitted/excluded from the data transfer. Activate

the desired control fields in the

area to exclude the respective parameters from the data

transfer.

Note: Observe "know-how" protection of the function block interconnection in the

application!

By default, the application download transmits HighLine information to the Servo Drives

9400 which provide for a subsequent display of function block interconnections active in

the device in the FB editor. Thus, the display of the function block interconnection is also

possible without the original »Engineer« project.

• In order to protect the know-how of your specific function block interconnection from

being read out of the device, the "application information" control field in the

area has

to be activated before starting the download. Thus, the »Engineer« does not transmit

any application information into the device. Hence, the function block interconnection

cannot be read out of the device subsequently. Tip: In this case, make sure that the

original »Engineer« project is available for service purposes.

• Click Detail... to get an overview of the parameters which are not transferred to the

device. The attached columns indicate why the respective parameter has been excluded

from the data transfer (source of exclusion). If selected, the column data correspond to
the selected control fields of

/ .

• The Options... button opens the dialog box Options which contains general settings for

transferring the data transfer.

Options

( 99)

5.

Click Next.
Step 2 - stop devices: Define the desired options for stopping the devices.

• When transferring data to several devices, in this step you can for instance define the

sequence in which the devices are to be stopped for the data transfer.

6. Click Next.
7. Confirm the query on whether the selected devices are to be stopped now with Yes to stop

the devices.
Step 3 - data transfer: The data transfer starts. The progress of data transfer is displayed.
Step 4 - Start devicesDefine the desired options (and for several devices, the sequence) for

starting the devices.

8. Click Complete.

• Start the selected devices.
• After a successful execution, the dialog box is closed automatically if you have activated

the Also show if successful option in the first step.