7 reading individual measured values, 8 comparing peak values, Reading individual measured values – Lenze Engineer v2.21 User Manual

Page 121: Comparing peak values, Device functions with active online connection

Advertising
background image

Lenze · Engineer · 2.13 EN - 10/2014

121

Device functions with active online connection

Data logger

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Automatic scaling function
Use the automatic scaling function to automatically scale and reposition the representation of

selectable signal characteristics in the oscillograph and reset the offset to "0".

How to carry out automatic scaling:

1. Go to the Data logger toolbar and click the

icon to activate the automatic scaling

function.

2. Select the channels/parameters for automatic scaling in the Select variable dialog box.
3. Press OK.

• The dialog box is closed and the selected channels/variables are scaled automatically.

7.7.2.7

Reading individual measured values

In addition to the zoom and scaling function, the data logger offers a "cursor function" that can be

used to display individual measured values of a selectable channel or the difference between two

measured values.

• If the Cursor has been pressed, the cursor function is active and two movable vertical measuring

lines are shown in the diagram.

How to use the cursor function:

1. Click the Cursor button.
2. Select the channel for which individual measured values are to be indicated from the

Channel list field.

3. Hold down the left mouse button and drag the red vertical measuring line to the desired

position.

• The active measuring line is represented by a continuous line, the inactive measuring

line is represented by a dotted line.

• If you position the mouse pointer over the inactive measuring line, the measuring line

automatically becomes active.

• The value measured at the position of the active measuring line is indicated in the Value

group field.

• The difference between the values measured at the two measuring lines is indicated in

the Differential value group field.

7.7.2.8

Comparing peak values

This function is available from »Engineer« V2.10!

Several values displayed in the data logger can be compared to each other using a horizontal

measurement line.

• The horizontal measurement line is displayed when the Cursor button has been pressed.
• The measurement line is automatically created based on the current cursor point and thus

cannot be shifted.