2 going online, Going online, Going online ( 77) – Lenze Engineer v2.21 User Manual

Page 77: Establishing an online connection, Stop

Advertising
background image

Lenze · Engineer · 2.13 EN - 10/2014

77

Establishing an online connection

Going online

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3. Confirm the note with OK.

• When the update has been executed successfully, the Build project dialog box is closed

and the Go online process is continued.

• If an error has occurred during the update, the Build project dialog box remains open. In

this case, please observe the messages in the "Build" window. Click Close to close the

dialog box and cancel the Go online process.

6.2

Going online

Going online with a changed project
When the Go online command is executed, the »Engineer« checks whether the current project

settings have been transferred to the devices. If one or several devices have the "changed" status, a

note asks you to update the project.

• Confirm the query in order to update the project. This serves to transfer the changes to the

device.

Build project

( 76)

How to go online to a device:

1. Select the device with which the online connection is to be established in the Project view

of the :

Tip: You can establish an online connection to all or multiple devices by selecting the

project root or a system module in the Project view. Then select the devices included in the

selected element for the online connection in the Communication path dialog box.

2. Click on the

icon or select the Online Go online menu command (keyboard command

<F4>).
If the changes made in the project have not been accepted yet, update the project.

Build

project

( 76)

If an update is to be carried out:

• Click Yes to open the Build project dialog box.
• Click Build in the Build project dialog box to update the changed project elements.
• When the update is completed, a note appears whether the update was successful.

If a communication path has not yet been set for the device, the Communication path

Stop!

If you change parameters in the »Engineer« while the controller is connected online, the

changes will be directly accepted by the controller!

Example 1: 9400 HighLine controller

Example 2: EL 870 controller and three axes