Defining, Element variables for "record" variable type, Defining the system functionality – Lenze Engineer v2.21 User Manual

Page 166

Advertising
background image

Defining the system functionality

Port editor (ports)

166

Lenze · Engineer · 2.13 EN - 10/2014

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.11.2.4

Defining element variables for "Record" variable type

The element variables of a port of the "Record" variable type can be changed/supplemented

subsequently any time via the Edit port dialog box if required.

How to generate a new element variable:

1. Select the port for the associated structure of which a new element variable is to be

generated in the Ports tab.

2. Click the Edit port... button.

• The Edit port dialog box appears:

3. Click the New button.

• The Element variable dialog box appears:

4. Enter a name for the element variable to be generated.
5. Select the data type for the element variable from the Type list field.

• In accordance with IEC 61131-3 integer data types can be selected.

6. Press OK.

• The dialog box is closed and the element variable is generated.

Advertising