Lenze · Engineer · 2.13 EN - 10/2014

135

Defining the system functionality

Parameter setting in the »Engineer«

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

• However, if an online connection to the device is available, the parameter list is in the "Online

mode". In this mode the parameter list displays so-called "Online parameters", presenting the

parameter settings which are currently existing within the device.

Altering parameters online

( 137)

• In the »Engineer« offline and online parameters are identified by a different background colour:

Tip!
In the information area below the parameter list the current mode (offline/online) is

displayed on the right side.
In order to show the parameter values as hexadecimal values, click the ViewShow values

in hex format menu item. This function has an effect on all parameters with integral

numerical values in dialogs and parameter lists.

Display parameters
"Display parameters" are parameters which are only used to show status information and actual

values and which feature a read-only access.

• In the »Engineer« display parameters are also identified by a different background colour:

8.6.2

Working in the parameter list

On the top edge (area ) the parameter list is provided with a toolbar which enables the parameter

transfer from the project into the device and vice versa.

• Click on an icon to execute the corresponding function.

Colour

Example

Meaning

White

Offline parameter

• The device is not connected "online" with the »Engineer«. The parameter value

set in the project is displayed.

Yellow

Online parameter

• The device is connected "online" with the »Engineer«. The current parameter

value of the device is displayed.

• The symbol behind a parameter value indicates that the value in the device

differs from the parameter value set in the project.

Red

Communication error (time-out) for an online parameter

• The communication connection to the device is interrupted.

Colour

Example

Meaning

Light grey

Offline display parameter

Pale yellow

Online display parameter

• The device is "online", i.e. connected to »Engineer«. The current parameter value

of a display parameter of the device is shown.

Red

Communication error (time-out) for an online display parameter

• The communication connection to the device is interrupted.