Error messages

This chapter describes the generators and their error messages that are called during the "Create"

process (

Build project

). The error messages are visible in the

Create

tab and are divided into different

categories: Error, warning, information.

Application Connection Generator

( 238)

PortLogic generator

( 241)

CAN generator

( 243)

Communication entity generator

( 249)

12.1

Application Connection Generator

Checking the connection between the port and the process data object

Dynamic creation of a PDO [AC0001]

Dynamic PDO for a port cannot be created [AC0002]

Dynamic ProcessDataObject for port cannot be created [AC0003]

Response (Lenze setting printed in bold)

Error  Warning  Information

Cause

Remedy

A port has not been specified by the user but has been

interconnected with another device. An attempt is made

to create a dynamic PDO for this port.

Check transfer parameters with the settings in the

application.

Process data objects ( 226)

Response (Lenze setting printed in bold)

Error  Warning  Information

Cause

Remedy

Communication entity not found

A port has not been specified but has been

interconnected with another device. An attempt is made

to create a dynamic PDO for this port. However, this

attempt fails because the device has no or several

communication interfaces.

Apply the port to a specific interface in the port editor.

Port editor (ports) ( 155)

Response (Lenze setting printed in bold)

Error  Warning  Information

Cause

Remedy

Communication entity not found

A port has not been specified but has been

interconnected with another device. An attempt is made

to create a dynamic PDO for this port. However, this

attempt fails because the device has no or several

communication interfaces.

Device is not provided with an interface enabling the

dynamic creation of a PDO, or the supply is used up.

• Apply port to a fixed PDO (8200 and 9300), or

• convert unused, unconnected ports to automatic

ports.