4 using the time axis, 5 starting/stopping recording, Using the time axis – Lenze Engineer v2.21 User Manual

Page 119: Starting/stopping recording, Using the time axis ( 119), Device functions with active online connection

Advertising
background image

Lenze · Engineer · 2.13 EN - 10/2014

119

Device functions with active online connection

Data logger

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.7.2.4

Using the time axis

The

icon in the Data logger toolbar serves to activate the "Time axis" mode for a continuous

measurement.
In this mode, the data memory for the measured data operates according to the ring buffer

principle, i.e. if the data memory is full and new measured data arrive, the oldest measured data will

be deleted. The time axis is tracking, similar to a cardiogram.

7.7.2.5

Starting/stopping recording

How to start/stop recording:
Click Start to start recording.

• Instead of Start the Stop button is displayed now.
• In the standard mode, recording automatically stops at the end of the time axis. The Stop

button serves to abort recording.

• In the "Time axis" mode, recording will only be stopped if you click Stop.

Post-trigger Select a positive delay time to detect signals occurring a certain time after the trigger

event.

Edge

If the trigger source is a channel or a variable, you can choose between the following

trigger modes:

Positive edge For triggering on a BOOL parameter:

• Trigger activation requires a FALSE-TRUE transition.

For triggering on a different parameter:

• For trigger activation, the selected trigger value must be exceeded.

Negative edge For triggering on a BOOL parameter:

• Trigger activation requires a TRUE-FALSE transition.

For triggering on a different parameter:

• For trigger activation, the selected trigger value must be fallen below.

Change For triggering on a BOOL parameter:

• Trigger activation requires a state change.

For triggering on a different parameter:

• For trigger activation, the current value must be different than the last value.

Setting

Function

Trigger event

Trigger

delay

(positive)

Trigger level

Note!

If you change the mode, the currently represented line diagram will be deleted.