3 vertical settings, Vertical settings, Device functions with active online connection – Lenze Engineer v2.21 User Manual

Page 114

Advertising
background image

Device functions with active online connection

Data logger

114

Lenze · Engineer · 2.13 EN - 10/2014

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.7.1.3

Vertical settings

The parameters to be recorded are configured via the list field below the diagram:

Column

Meaning

-

Curve colour for the representation in the diagram

• Double-click this field to open the Colour dialog box for selecting another curve colour.

Ch

Channel number

• Read only

On

On/off

Inv

Inversion on/off

Code

Code of the parameter to be recorded

• Read only

Subcode

Subcode of the parameter to be recorded

• Read only

Device

Name of the device that contains the parameter to be recorded.

»Engineer« From »Engineer» V2.10

, the data logger is also available for the upper project

element, for system modules, and for axes for a cross-device recording. In this case, the

list field additionally contains the "device" column.

Name

Name of the parameter to be recorded

• Double-click this field to open the Insert channel dialog box for selecting the parameter

to be recorded.

Selecting the variables to be recorded ( 116)

Unit

Scaling

• Double-click this field to open the Scaling dialog box for setting the scaling for the

parameter to be recorded.

1/Div

Vertical scale factor

• Click this field to open the list field for selecting the vertical scale factor.

Offset

Offset value

• The offset value depends on the scale factor and is marked by a dashed line in the curve

colour in the left-most position of the diagram.

Position

Position value

• The position value is independent of the scale factor and marked by a line in the left-most

position of the diagram.

Advertising