_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Node does not support any SYNC slave functions [NWCAN0015]

Node does not support any SYNC master function [NWCAN0016]

Node is SYNC sender and receiver at the same time [NWCAN0017]

Object cannot be transferred. Node not a SYNC slave [NWCAN0026]

12.3.4

COB-ID

Stock of CAN IDs exhausted [NWCAN0018]

Response (Lenze setting printed in bold)

Error  Warning  Information

Cause

Remedy

Node does not support a sync slave function.

Response (Lenze setting printed in bold)

Error  Warning  Information

Cause

Remedy

Node does not support a SYNC master function.

Response (Lenze setting printed in bold)

Error  Warning  Information

Cause

Remedy

Reserved

Response (Lenze setting printed in bold)

Error  Warning  Information

Cause

Remedy

The node specified either operates with synchronised

process data objects or processes (tasks). However, the

node has not been declared as synchronisation object

receiver.

Make the following choice for the node in the

Synchronisation tab of the indicated network under

SYNC receivers:

• Transfer/receive synchronised process data objects

• Synchronise processes (tasks)

Response (Lenze setting printed in bold)

Error  Warning  Information

Cause

Remedy

Too many communication objects are transferred in the

indicated network.

Available COB-IDs are no longer provided.

• Reduce number of port connections

• Extend the COB-ID identifier range in the Settings tab

of the network specified.

Caution:

The default range is designed in a manner that also

enables old Lenze devices like 9300 and 8200 to operate

with it.