3 can generator, 1 addresses, Can generator – Lenze Engineer v2.21 User Manual

Page 243: Error messages

Advertising
background image

Lenze · Engineer · 2.13 EN - 10/2014

243

Error messages

CAN generator

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

12.3

CAN generator

Addresses

( 243)

Baud rate and MMT master

( 244)

Synchronisation

( 245)

COB-ID

( 246)

Ports and PDO

( 248)

12.3.1

Addresses

Invalid value range for addresses (min and max inverted?) [NWCAN0001]

Number of nodes for the network exceeded [NWCAN0002]

Node address for nodes beyond the value range [NWCAN0003]

Node address for node already exists [NWCAN0004]

Response (Lenze setting printed in bold)

Error  Warning  Information

Cause

Remedy

In the CAN network, Settings tab, the minimum and

maximum addresses of the possible address range have

been inverted.

Accordingly alter the range, so that the minimum

address is smaller than the maximum address.

Response (Lenze setting printed in bold)

Error  Warning  Information

Cause

Remedy

More nodes than permitted in the "Settings" tab of the

CAN network are assigned to the CAN network.

• Remove nodes that are not required from the

network

or

• Increase the maximum permissible number of nodes

in the "Network/settings" tab.

Response (Lenze setting printed in bold)

Error  Warning  Information

Cause

Remedy

An invalid node address has been entered for the node

specified.

Change the node address so that it is within the

permissible value range.

Response (Lenze setting printed in bold)

Error  Warning  Information

Cause

Remedy

An already existing node address has been entered for

the node specified.

Change the node address so that a number is selected

that has not been allocated before.