Inserting & configuring a network – Lenze Engineer v2.21 User Manual

Page 209

Advertising
background image

Lenze · Engineer · 2.13 EN - 10/2014

209

Inserting & configuring a network

Inserting a network

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Step 3 - Settings
In the case of an ETHERNET Powerlink network, the Baud rate selection field is not

available.

7. Highlight the control field entitled Insert machine application and add nodes if all existing

devices are to be automatically added to the network as nodes.

• If the control field has been highlighted, a machine application that is shown in the

project tree is also added to the project. The selected applications are already integrated

in the machine application.

• The indicated default values for Lenze devices do not need to be changed in the settings

area.

• All compatible network nodes which are below the network system module are added

to the network. If a device has several node interfaces of the same type, a selection

dialog appears.

• All assigned network nodes are pre-assigned addresses in ascending order. In the case of

CAN, the minimum address is taken from the settings.

8. Click the Next button.

• An information text appears.

You can either alter the node addresses in the »Engineer« project or at the hardware

switches.

9. Press Complete.

• The selected network is inserted into the highlighted element.

Advertising