Wire the motor/resistive brake (bc) connector, 24v dc brake input power connections, Rbm module connections – Rockwell Automation 2094-xMxx-S Kinetix 6000 Multi-axis Servo Drives User Manual User Manual

Page 111: To wire the motor/resistive brake (bc) connector

Advertising
background image

Rockwell Automation Publication 2094-UM001H-EN-P - June 2013

111

Connecting the Kinetix 6000 Drive System

Chapter 5

Wire the Motor/Resistive Brake (BC) Connector

This example applies to AM modules and the inverter section of IAM modules.

Figure 60 - IAM/AM Module (BC connector)

24V DC Brake Input Power Connections

RBM Module Connections

Table 75 - Motor/Resistive Brake (BC) Connector

MBRK

-

MBRK+

COM

PWR

DBRK

-

DBRK+

1 2 3 4 5 6

Kinetix 6000 IAM/AM Module
(IAM module is shown)

Motor/Resistive Brake

(BC) Connector

IMPORTANT

If your system includes a LIM module, you can source the 24V DC from the LIM
module (P1L or PSL connector).

Table 74 - Motor/Resistive Brake (BC) Connector

2094-ALxxS, 2094-BLxxS,

2094-XL75S-Cx LIM Modules

2094-AL09 and 2094-BL02

LIM Modules

BC Connector

(IAM/AM modules)

P1L Pin

Signal

PSL Pin

Signal

BC Pin

Signal

1

IO_PWR2

1

MBRK PWR

3

PWR

2

IO_COM2

2

MBRK COM

4

COM

RBM Module I/O Connections

BC Connector

(IAM/AM modules)

TB3 Pin

Signal

MP Pin

Signal

(1)

(1) Firmware revision 1.071 or later is required to use the DBRK outputs on the Kinetix 6000 IAM/AM module.

6

COIL_A1

1

DBRK+

7

COIL_A2

2

DBRK-

Advertising