Calculate additional bus capacitance, Bulletin 2094 drive capacitance values – Rockwell Automation 2094-xMxx-S Kinetix 6000 Multi-axis Servo Drives User Manual User Manual

Page 227

Advertising
background image

Rockwell Automation Publication 2094-UM001H-EN-P - June 2013

227

DC Common Bus Applications

Appendix C

Calculate Additional Bus
Capacitance

Additional bus capacitance is the sum of all follower IAM, AM, and IPIM
module capacitance values for your Bulletin 2094 common-bus modules.
Specifically, this includes the capacitance values for each of these modules:

Each follower IAM (converter and inverter) module
Each AM module on the follower IAM module power rail
Each IPIM module on the follower IAM module power rail

Enter the additional bus capacitance value in Set the Additional Bus Capacitance
Parameter
beginning on

page 230

.

Bulletin 2094 Drive
Capacitance Values

Use these tables when calculating total bus capacitance and additional bus
capacitance for your Bulletin 2094 common-bus application.

Table 117 - IAM/AM (200V-class) Modules

Table 118 - IAM/AM (400V-class) Modules

Table 119 - Shunt Module (200/400V-class)

Table 120 - IPIM Module (400V-class)

IAM Converter (200V-class)

Capacitance
μF

AM Inverter (200V-class)

Capacitance
μF

2094-AC05-MP5-x

270

2094-AMP5-x

390

2094-AC05-M01-x

2094-AM01-x

660

2094-AC09-M02-x

540

2094-AM02-x

780

2094-AC16-M03-x

1320

2094-AM03-x

1320

2094-AC32-M05-x

1980

2094-AM05-x

2640

IAM Converter (400V-class)

Capacitance
μF

AM Inverter (400V-class)

Capacitance
μF

2094-BC01-MP5-x

110

2094-BMP5-x

75

2094-BC01-M01-x

2094-BM01-x

150

2094-BC02-M02-x

220

2094-BM02-x

270

2094-BC04-M03-x

940

2094-BM03-x

840

2094-BC07-M05-x

1410

2094-BM05-x

1175

Shunt Module
(200/400V-class)

Capacitance

μF

2094-BSP2

470

IPIM Module (400V-class)

Capacitance

μF

2094-SEPM-B24-S

840

Advertising