Apply the Motor Cable Shield
Clamp

This procedure assumes you have completed wiring your motor power (MP)
connector and are ready to apply the cable shield clamp.

Follow these steps to apply the motor cable shield clamp.

1. Depress the spring loaded clamp.

2. Position the exposed portion of the cable braid directly in line with the

clamp.

3. Release the spring, making sure the cable and cable braid are held secure by

the clamp.

4. Attach tie wrap (slide-open clamp only) around cable and clamp for

additional strain relief.

5. Repeat

step 1

through

step 4

for each IAM, AM, or IPIM module.

TIP

Your drive can be equipped with either the pivot-open or slide-open cable
clamp.

Screwdriver Tip

3.5 mm (0.14 in.)

Screwdriver

Tip in Slot

Slide-open Cable Clamp

Pivot-open Cable Clamp

Pry clamp back
with thumb.

The pivot-open cable clamp was designed to
replace the slide-open cable clamp.
Pivot-open clamp features include:
Screwdriver not required for depressing

the spring

Tie wrap not required or recommended

Tie Wrap

Outer Insulation

Motor Cable

Exposed Braid
(under clamp)

Slide-open Cable Clamp

Vent holes on top

of IAM/AM module.

Motor

Cable

Exposed Braid

(under clamp)

Cable Clamp

Outer Insulation

Horizontal Cable Clamp Orientation Examples

Vertical Cable Clamp

Orientation Example

Motor Cable

Outer Insulation

Exposed Braid
(under clamp)

Pivot-open Cable Clamp

Vent holes on top of IAM/AM module.