Changing the Default IDN Parameter Values

This appendix provides a procedure, specific to the Kinetix 6000 (sercos) drive
systems, for changing IDN parameter values to non-default values when your
application does not match the default configuration. The procedure also applies
when one or more Kinetix 6000M IDM systems are present.

Before You Begin

The Logix5000 processor contains a motion planner that sends real-time and
non real-time data to the drive. This drive communication is performed via a set
of sercos interface telegrams. Each telegram has an identification or Ident (IDN)
number. All parametric data, such as scaling and loop gains, and real-time loop
closure information is configured this way.

Table 127 - IDN Instruction Format in the IEC Standard Document

There are default parameters in the Logix5000-to-Kinetix 6000 drive product
structure you can reconfigure when the default configuration does not match the
Integrated Architecture™ machine configuration.

By using this procedure, you can change the Additional Bus Capacitance value in
common-bus configurations.

Topic

Page

Before You Begin

249

Change IDN Parameter Values

250

IDN Number

Name

Function/Description

Length
in bytes

Minimum
input value/
Maximum
input value

Scaling/resolution

Units

TIP

You can also set the Additional Bus Capacitance parameter by using DriveExplorer
software (refer to

Appendix C

), the Logix Designer application, or RSLogix 5000

software, version 20.00 or later, from I/O configuration>Sercos module>Drive
module properties>Power tab (refer to

Chapter 6

).