Iam and am motor power and brake connector pinout – Rockwell Automation 2094-xMxx-S Kinetix 6000 Multi-axis Servo Drives User Manual User Manual

Page 66

Advertising
background image

66

Rockwell Automation Publication 2094-UM001H-EN-P - June 2013

Chapter 4

Connector Data and Feature Descriptions

IAM and AM Motor Power and Brake Connector Pinout

Table 35 - Motor Power Connector

Table 36 - Motor Brake/Resistive Brake Connector

MP Pin

Description

Signal

4

Chassis ground

3

Three-phase motor power

W

2

V

1

U

IMPORTANT

Combined motor-power cable length for all axes on the same DC bus must not
exceed 240 m (787 ft) with 460V systems or 160 m (525 ft) with 230V systems.
Drive-to-motor power cables must not exceed 90 m (295.5 ft).

System performance was tested at these cable length specifications. These
limitations also apply when meeting CE requirements.

BC Pin

Description

Signal

6

Motor brake connections

MBRK-

5

MBRK+

4

Motor brake common

COM

3

+24V brake input power
(from LIM module or customer supplied)

PWR

2

RBM module connections
(from RBM module and safety string)

DBRK-

1

DBRK+

Advertising