Analog Outputs

The IAM and AM modules include two analog outputs (IOD-23 and IOD-25)
that you can configure through software to represent drive variables.

Figure 31 - Analog Output Circuit

Table 39 - Analog Output Specifications

Table 40 - Linear Scaling Specifications

For configuration/set up of the analog outputs, refer to Configure Drive
Parameters and System Variables
beginning on

page 160

.

CH1

CH1

CH2

CH2

DAC

Oscilloscope

Kinetix 6000 IAM/AM

Module

(second channel not shown)

IMPORTANT

Output values can vary during powerup until the specified power supply
voltage is reached.

Parameter

Description

Min

Max

Resolution

Number of states that the output signal is divided into, which
is 2

(to the number of bits)

.

±11 bits

Output current

Current capability of the output.

0

+2 mA

Output signal
range

Range of the output voltage.

2094-xCxx-Mxx and
2094-xMxx drives

0

+5V

2094-xCxx-Mxx-S
and 2094-xMxx-S
drives

0

+10V

Offset error

Deviation when the output is expected to be at 0V.

1 mV

Bandwidth

Frequency response of the analog output

DC

7.2k Hz (3 db)

Drive Cat. No.

Speed
rpm

Value
V DC

Torque
%

2094-xCxx-Mxx
or 2094-xMxx

10,000

5.0

1000

0

2.5

0

-10,000

0

-1000

2094-xCxx-Mxx-S
or 2094-xMxx-S

10,000

10.0

1000

0

5.0

0

-10,000

0

-1000