Set the Additional Bus
Capacitance Parameter

In this section you set the Add Bus Cap parameter by using DriveExplorer
software.

The following hardware and software tools are required to provide the necessary
communication link between your personal computer and the Kinetix 6000 drive
system running DriveExplorer software.

Table 121 - Kinetix 6000 System Requirements

Remove Sercos Communication

Follow these steps to remove (break) sercos communication.

1. Remove three-phase and control power from the Kinetix 6000 drive

system.

2. Remove one of the sercos fiber-optic cables.

Fiber-optic cable connections (Tx and Rx) are on the top of each IAM and
AM module.

3. Re-apply three-phase and control power.

TIP

You can also set the Add Bus Cap parameter by changing IDN parameter
values. Refer to

Appendix E

on

page 249

for more information.

TIP

You can use this procedure to change other parameters too, the Analog
Output parameters, for example.

Description

Cat. No.

Version

DriveExplorer software

(1) (2)

(1) Refer to DriveExplorer Getting Results Manual, publication

9306-GR001

, for instructions.

(2) Additional information regarding these communication and software tools is available at

http://www.ab.com/support/abdrives

.

9306-4EXP02ENE

2.01 or later

Serial to SCANport adapter

(2) (3)

(3) Refer to 1203-SSS (series B) FRN 3.xxx User Manual, publication

20COMM-UM001

, for instructions.

1203-SSS (Series B)

3.004 or later

Studio 5000 Logix Designer application

9324-RLD300xxE

21.0 or later

RSLogix 5000

software

15.0 or later

ATTENTION: To avoid personal injury or equipment damage, at least one end of
a sercos fiber-optic cable must be disconnected from the drive. This makes sure
that motion does not occur while changes are being made to the Add Bus Cap
parameter.