Set the additional bus capacitance parameter – Rockwell Automation 2094-xMxx-S Kinetix 6000 Multi-axis Servo Drives User Manual User Manual

Page 230

Advertising
background image

230

Rockwell Automation Publication 2094-UM001H-EN-P - June 2013

Appendix C

DC Common Bus Applications

Set the Additional Bus Capacitance Parameter

Follow these steps to set the Additional Bus Capacitance parameter.

1. Start your DriveExplorer software.
2. From the Explore menu, choose Connect>Local or press CTRL+L.

DriveExplorer software will read your system.

3. Observe the Linear List of parameters as grouped by Node, Port, and Axis

hierarchy as shown below.

4. Choose Devices>Node>Product and navigate to the parameter x:x:x599

as shown below.

5. Double-click the x:x:x599 Add Bus Cap parameter.

N: P. x xxx

Network Node Number

DPI Port Number

Parameter Number
30 = Version Data

Linear List Legend

Axis Number
0 = IAM (axis 1)
1 = AM (axis 2)
2 = AM (axis 3)
3 = AM (axis 4)