Shunt Module Wiring Examples

Refer to Kinetix Motion Accessories Technical Data, publication

GMC-TD004

for the Bulletin 1394 external shunt module catalog numbers available for the
Kinetix 6000 drive systems.

Figure 95 - Shunt Module Wired for Internal Operation (default configuration)

Refer to the Kinetix 6000 Shunt Module Installation Instructions, publication

2094-IN004

, for additional installation information.

Figure 96 - Shunt Module with External Passive Shunt

Refer to the External Shunt Module Installation Instructions, publication

2090-

IN004

, for additional installation information.

COL

INT

DC+

TS2
TS1

2

1

3

2

1

2094-BSP2

Kinetix 6000

Shunt Module

External Shunt Resistor

(RC) Connector

External Thermal Switch

(TS) Connector

COL

INT

DC+

2

1

3

2

1

TS2

TS1

COL

DC+

2094-BSP2

Kinetix 6000

Shunt Module

Bulletin 1394

External Passive

Shunt Module

External Shunt Resistor

(RC) Connector

External Thermal Switch

(TS) Connector

Resistor

Thermal
Switch

IMPORTANT

Only passive shunts with a thermal switch are wired to the TS connector on the
Kinetix 6000 shunt module. If your external passive shunt does not have a
thermal switch, leave the jumper (default configuration) in place on the TS
connector.