Anti-Passback

55

6

To define readers, you can use GV-ASKeypad or the Web interface of the GV-AS Controller.
Here we use the GV-AS400 Web interface as example to define Wiegand readers. For this
case, Wiegand reader A (Entry) goes from Outside to Reception, Wiegand reader B (Exit)
goes from Reception to Outside and etc.

Figure 6-5

6.3.4 Step 4: Configuring Door Contacts

This step is to define the door contact sensor for each door/gate. When the door contact
sensor is triggered and the door is unlocked, the GV-ASManager can tell where a card holder
is based on your area definition at Step 1.

To define door contact sensors, you need to use the Web interface of GV-AS Controller. In
this example of GV-AS400 Web interface, Input 01 is used as Door Contact of Door A, Input
02 is used as Door Contact of Door B and etc.

Figure 6-6