Enabling alarm reporting – Verilink Access Manager 2000 (896-502037-001) Product Manual User Manual

Page 144

Advertising
background image

Configuring the T1 Network

5-20

Access Manager 2000 User Manual

Specifics are given in Table 5-4, “Selecting baud rates by equipment type
and access type”.

Table 5-4

Selecting baud rates by equipment type and access type

Note:

Newer revisions of the 551VST List 2, 551VST ML List 2, SIM,
and NC/E can be accessed in dial-up mode using the Hayes

protocol at either 1200 or 2400 baud with an external modem.
Existing revisions of the above products can be upgraded to this
capability with a firmware change.

The

Enable Alarm Reporting

option tells a node that alarm

messages should be sent to Access Manager either as they occur or when
the node is accessed.

Only a node that has alarm reporting capability can have this option set to

YES

and then only if access to the node is through a direct connection,

modem, or ComDesign multiplexer. Access System equipment is also
compatible with the X.25 PAD (Packet Assembler Disassembler).

If access to the circuit elements in a node is through the ESF Facility Data
Link, set this option to

NO

.

The following types of nodes can report alarms:

551VST List 2

551VST ML List 2 without ASCII interface firmware

Type of access

Equipment type

Direct

Modem

ComDesign
Mux

X.25 PAD

• 551 VST List 2

• 551 VST ML List 2

• SIM

• NC/E

9600

1200 o
2400

9600

Not applicable

Access System 2000

9600

9600

9600

9600

All other equipment

Can only be accessed at 1200 baud.
For direct interface or 4-wire dedicated
modem, set baud rate to either 1200 o
9600.

Not applicable

Enabling alarm
reporting