Configuring the T1 Network

5-62

Access Manager 2000 User Manual

This option determines whether the circuit element is installed and
operational. This option, marked with an asterisk (*), must be set to

YES

to enable any of the subsequent options (including collection of
performance monitoring data, alarm reporting, and so on).

Before Access Manager will allow you to set this option to

YES

for the

circuit element, you must set the

Installed and Operational

option for the circuit element’s parent node to

YES

.

The default setting is

NO

.

Performance data is stored in registers of CSU circuit elements. Each
CSU circuit element has registers to store data. Access Manager can
access these registers through the

Retrieve Performance Data

function. Use the following conditions for setting this field:

If the circuit element is accessed only through the ESF Data Link,
set this option to

NO

, regardless if performance data is to be

retrieved. A CSU accessed only by the ESF Data Link is a far-end
CSU, and it should have its data collected by the near-end CSU.

If the CSU circuit element is a near-end CSU, set this option to

YES

if retrieval of near-end or far-end performance data is desired.

Setting

Retrieve Performance Data

to

YES

is sufficient to

enable retrieval of near-end performance data, but not sufficient to
retrieve far-end performance data. For this, you’ll need to set the

Retrieve Far-End Performance Data

option.

Enable EQP SIde B8ZS Decode

Regenerate CRC to EQP

EQP Side ESF Framing

Enable YEL Transcode to EQP

Idle Code Flags

a. For a remote 4016 L1, you must set this option through the hardware.

KEY:

= available

= available in some revisions =

not available

standalone CSUs

551VST-type CSU configuration
option

List 1/A

List 1/B

List 2

4016-R

4016 L1 4016 L2

Installed and
Operational

Retrieve
Performance Data