Repeate loopback time- out – Verilink Access Manager 2000 (896-502037-001) Product Manual User Manual

Page 189

Advertising
background image

Configuration Options for 551VST Elements

Access Manager 2000 User Manual

5

-65

Table 5-8

Older CSU Circuit Elements BER Alarm Rest Time

Table 5-9

Newer CSU Circuit Elements BER Alarm Reset Time

The longer BER alarm reset times reduce the number of BER alarms reported to
Access Manager.

The repeater loopback time-out is the time period after which the repeater
loopback (RLB) automatically releases. It has a default value of 300
seconds(5 minutes).

An RLB loops the CSU transmit-side output towards the equipment
(EQP) through the CSU repeater and disconnects the incoming signal
from the NET. Without this time-out, there would be no ESF Data Link
access path to the CSU from the far-end to tell the CSU to drop the
loopback. The RLB time-out therefore drops the loopback after the time-
out period has elapsed.

Applicable equipment:

BER Threshold

Alarm Reset

• 551VST List 1/A, all revisions

• 551VST List 1/B BER alarm, all

revisions

• 4016 List 1, all revisions

• 4016 List 2, firmware revision 2.2

or earlier

• 4016-R, firmware revision 2.4 o

earlie

• 551VST List 2, firmware revision

2.1 or earlie

10

-4

4 seconds

10

-5

4 seconds

10

-6

10 seconds

10

-7

70 seconds

10

-8

70 seconds

10

-9

660 seconds

Applicable equipment:

BER Threshold

Alarm Reset Times

• 4016 List 2, firmware revision 2.3

or later

• 4016-R, firmware revision 2.5 or

later

• 551VST List 2, firmware revision

2.2 or later

10

-4

97 -194 seconds

10

-5

97 -194 seconds

10

-6

97 -194 seconds

10

-7

97 -194 seconds

10

-8

453 - 906 seconds

10

-9

647 - 1,294 seconds

Repeate
Loopback Time-
out

Advertising