As2000 node – Verilink Access Manager 2000 (896-502037-001) Product Manual User Manual

Page 287

Advertising
background image

Displaying individual circuit element status

Access Manager 2000 User Manual

8-17

Note:

The single-line 551VST List 1/A and List 2 also have an Enable
Alarm Latch configuration, showing whether the local BER
alarm deactivates on clearing (NO) or stays on until manually
cleared (YES).

To view the current status for a AS2000 or ConnecT1 Plus circuit
element:

Move the cursor to

Status-Element

, and press

. A

Circuit

Status screen for the first circuit element appears. Each type of circuit
element has specific screen.

The circuit elements and their corresponding screens are as follows:

CRC/Frm Bit Errors

Yes, No The framing bit error are being received

from the EQPT, while no CRC errors are
being received from the NET.

For ESF framing,

YES

indicates that

CRC errors are being received.

For SF (D4) framing,

YES

indicates that

frame bit errors are being received.

BPV Errors

No

BPV error are not being received fro
either the EQPT side or NET side.

DTE (EQPT)/SPAN
(NET) Looped

No

Neither an RLB nor an ELB is in progress
(EQPT side), and either an LLB or PLB is
in progress (NET side).

ESF Framing toward
the NET

Yes

But since ESF toward the EQPT is NO, the
framing toward the EQPT is SF.

B8ZS Encode

No

Neither the network (NET) nor the
equipment (EQPT)is set for B8ZS line
coding (transmit direction).

B8ZS Decode

No

Neither the NET nor the EQPT is set for
B8ZS decoding (receive direction).

Regen Transmit CRC

YEL AL Tran Enable

No

YEL AL Transcode
To

No

Yellow alarms are not currently being
transcoded from the network to the
equipment, or from the equipment to the
network.

Field

Value

Meaning

AS2000 node

Enter