Configuration Options for AS2000 and ConnecT1 Plus

Access Manager 2000 User Manual

5

-77

If you set the

Retrieve Far-End Data

option to

YES

, you must

also set the

Retrieve Near-End Data

option to

YES

, and there

must be a circuit built between the near-end and far-end circuit elements.

Do not set

Retrieve Far-End Data

to

YES

at both the near-end

and far-end circuit elements. For example, set

Retrieve Far-End

Data

to

YES

for the near-end NCC, CCC, or TAC and set

Retrieve

Far-End Data

to

NO

for far-end circuit element. The defaults for

these options is

NO

, except near-end

Net Use

, which is

YES

.

This option must be set to

YES

and the

Installed and

Operational

option must also be set to

YES

to enable Access

Manager to configure the selected CSU circuit elements.

The options following

Save Configuration to CSU

are

downloaded to the CSU circuit element when

is pressed. If this

option is set to

NO

, any changes made are saved in the database but are

not downloaded to the CSU circuit element.

CSUs can report alarm conditions to Access Manager when excessive
errors occur or the line service is degraded.

If you don’t want the CSU to report alarm conditions to Access Manager,
your choice is simple. Set the

Enable Alarm Reporting

field to

NO

.

To allow the CSU to report alarm conditions to Access Manager:

1. Set

Enable Alarm Reporting

to

YES

.

2. Make sure that in the Node Configuration screen of the parent node,

you have:

set the

Enable Alarm Reporting

to

YES

downloaded the alarm path for that node

Otherwise, the CSU will send alarms to the node controller, but the
node controller will not forward these alarms to Access Manager.

Save
Configuration to
CSU

F5

Enable Alarm
Reporting