Configuration Options for AS2000 and ConnecT1 Plus

Access Manager 2000 User Manual

5

-99

Installed and Operational

This setting should be the same as the

Installed and

Operational

option setting for the associated CSU.

Save Configuration to DIU

To store the configuration from the database into the DIU, set the

Save

configuration to DIU

option to

Y

. If this option is set to

N

, any

updated changes are saved to the database but are not downloaded to the
DIU.

Connected CSU Shelf and Plug Numbers

Specify the AS2000 shelf number and plug-in module slot number of the
CSU associated with the selected DIU 2140. The shelf number can be
from 1 to 4. The plug-in module slot number can be from 1 to 13 for a
multiline shelf or 1 to 2 for a dual-line shelf.

Channel Assignment

Assign an available DS0 channel of the associated DS1 line to the DIU.
This number can be from 1 to 24.

This parameter also has an

key associated with it so that you can

view the allocated channels. For additional information, see “Channel
Assignment” on page 5 -93.

Mode

To select the transmission mode of the DIU 2140, press

in the

Mode

field. The Select Mode screen will appear.