Configuring nodes

Access Manager 2000 User Manual

5

-21

SIM

NC/E

Access System 2000

The node will auto-dial Access Manager and report status changes if both
of these conditions are met:

a. the

Enable Alarm Reporting

option is set to

YES

, and

b. the

Alarm Path

option is set to anything other than

NONE

or

DIREC

.

For all of the latest revisions of the above listed multiline nodes (not the
single-line 551VST List 2), if

Alarm Path

is set to

NONE

and

Enable Status Change Reporting

is

YES

, these circuit

elements will report all accumulated uncleared alarms to Access Manager
when they are contacted by Access Manager either during on-line access
or scheduled polling.

Selecting options based on access arrangement

To continue configuring the node, you must view the following tables and
select the appropriate data to enter into upcoming fields.

Table 5-8, “Older CSU Circuit Elements BER Alarm Rest Times

Table 5-9, “Newer CSU Circuit Elements BER Alarm Reset Times

Choose the table for your specific type of node.

Each column is an access arrangement type. Determine which column
applies to the node you are adding. Enter the values in that column when
you configure the node.

The access arrangement types listed in these tables are:

Direct: The node’s network management port connects directly to a
comline on the Access Manager host PC.

Modem: The node’s network management port connects to a
modem that receives calls from the Access Manager host PC and if
enabled, calls Access Manager to report alarms.

None: The node’s network management port is not used. Access to
the node is limited to the Facility Data Link (which implies you’re
dealing with a far-end node) or via daisy chain.