Analyzing Performance Data

7-6

Access Manager 2000 User Manual

FCOCO: Central Office-to-Central Office (interoffice) long
circuit length (greater than 1000 airline miles). This filter
performs a 24-hour data analysis based on the standard tariff of
99.3% error-free seconds and 99.85% availability.

ACPCP: Average Customer Office-to-Customer Office
(interoffice). This filter performs a 24-hour data analysis based
on the standard tariff of 96.5% error-free seconds and 99.7%
availability.

P-User: This filter allows you to set the filter thresholds as
percentages of error-free seconds and availability.

S-User: This filter allows you to define the thresholds in terms
of seconds per 15-minute interval for ES, UAS, BES, SES,
LOFC, ES-L, SEFS, and OOFS. Only the register intervals that
exceed the thresholds are displayed.

Bar Chart: This additional option allows you to observe a
graphic display of the performance data for the 24-hour period
selected. The data displayed depends on the hardware revision
level of the CSU circuit element whose data is requested. For
AS2000 circuit elements, the data displayed depends on the
register set (USER, Additional, etc.) selected. 551VST type
hardware revisions 2.0 and earlier show only the ES, UAS, BES,
and SES data.

4. If

you

choose

P-Use

, the Select Minimum Threshold(s) screen

appears.

Enter the desired percentage of error-free seconds and percent
availability threshold settings and press

to accept the

thresholds. If you only want to inspect one of these thresholds, enter
a zero to disable either threshold check.

F5